Aixplorer Ultrasound Machine Repair Self-Test Failed And Unable To Enter The System
1. Repair time: 2-4 days
 2. Warranty: 60 days
 3. Fault phenomenon:
This fault is generally a front-end and back-end communication problem. Consider the channel board and its connecting wires
 Repair result: Unplug and plug the connection cable from the channel board to the PC, and the fault is eliminated
Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/maintenance range.
Other ultrasound parts related to GE that we can offer:
| GE | vivid E9 | BEP Power P/N::GA200040 or 5145000-10 | 
| GE | vivid E9 | Main Power P/N::GA200004 | 
| GE | vivid E9 | Control Panel | 
| GE | Logiq E9/vivid E9 | GTX 2.4/GTX-TLP 3.0:5201044-3,5201044-4, 5201044-5 / GA200625-3 | 
| GE | Logiq E9 | MRX Board P/N:5393908 | 
| GE | Logiq E9/vivid E9 | GFI2 P/N:25161631 | 
| GE | Logiq E9 | BEP Power 5393800-3,5166790-2/5393801 | 
| GE | Logiq E9 | Main Power P/N:: 5205052-3 | 
| Logiq E9 | Control Panel board 9375-00639-001/2 | |
| GE | Logiq E9/vivid E9 | Touch ScreenCORE OPERATOR PANEL, UPPER 4- touch panel GB200091/5207000-53 | 
| GE | Logiq E9 | Trackball | 
| GE | Logiq E9 | GE Logiq E9 19" LCD 5392293-21, KT-LM190SDG-U | 
| GE | Voluson E6/E8 | RSR14.P9 KTI196357 | 
| GE | Voluson E6/E8 | RST20.P8 KTI301148_2 | 
| GE | Voluson E6/E8/E10 | RSX | 
| GE | Voluson E6/E8/E10 | RFM201 FE mainboard | 
| GE | Voluson E6/E8/E10 | RFM221 FE mainboard | 
| GE | Voluson E6/Voluson E8 | RFI/ RFI21b Board KTI300614_4 /KTI302197_6, RFI6g.P4 :KTI196142 | 
| GE | Voluson E6/Voluson E9 | KTI302171-4 | 
| GE | Voluson E6/Voluson E8 | RSR P/N:KTI301394-2/KTI196357/KTZ196310 | 
| GE | Voluson E6/Voluson E8 | AC/DC Power P/N:KTI300627-4/KTI300242-3 | 
| GE | Voluson E6/Voluson E8 | RSP2.PX EC250 Power P/N: KTZ302752 | 
| GE | Voluson E6/Voluson E8 | GBF80A KTI300741 | 
| GE | Voluson E6/Voluson E8 | GE Voluson E8 C2D E6400 BEP Board P/N KTI302072 | 
Knowledge point
Aixplorer® Ultimate is a premium ultrasound system leveraging the unique UltraFast™ technology in which the frame rate is 200 times faster than conventional ultrasound systems. Its software-based architecture has allowed SuperSonic Imagine to continuously offer innovative and increasingly efficient imaging modes.
Our pioneering technology, ShearWave™ Elastography (SWE), is the only technique capable of non-invasively measuring tissue stiffness in a wide range of clinical applications and with all probes in real-time.
With Aixplorer Ultimate, you can enjoy innovation exponentially: everything works faster and even better.
Exceptional image quality
SuperSonic Imagine's UltraFast software technology provides a high quality, homogeneous and information-rich image for a wide variety of clinical situations. Also, thanks to TissueTuner™ technology, the speed of the ultrasound can be adapted for multiple organs and is well suited for a variety of clinical situations.
The only real-time ShearWave Elastography
Real-time ShearWave Elastography, pioneered by SuperSonic Imagine, allows physicians to visualize and quantify the stiffness of tissue in a real-time, reliable, and reproducible manner. Tissue stiffness has become an important parameter in diagnosing potentially malignant tissue or other diseased tissue. Almost 400 peer-reviewed publications have demonstrated the value of SWE for the clinical management of patients in a wide range of diseases.

Precautions for Maintenance
Before delivery, we'd like to confirm the below details of your defective ultrasonic board.
Have your board ever repaired? ( Better to be never repaired)
Is the board original in complete condition?
What's the detailed faults? ( Send me fault description, fault image or video)
Your answers will help our repair engineers team to prejudge whether it's repairable.
|   | 
| Aixplorer Ultrasound Machine Repair Self - Test Failed And Unable To Enter The System Images | 
 Preirus Troubleshoot Ultrasound Machine Repair Hitachi Aloka
                                                                                        
                                                        
                        
                        
                        
                                                            Preirus Troubleshoot Ultrasound Machine Repair Hitachi Aloka
                                                    
                        
                     S2000 Color Doppler Medical Machine Repair For Startup Failure
                                                                                        
                                                        
                        
                        
                        
                                                            S2000 Color Doppler Medical Machine Repair For Startup Failure
                                                    
                        
                     GE Clinic Ultrasound Machine Repair
                                                                                        
                                                        
                        
                        
                        
                                                            GE Clinic Ultrasound Machine Repair
                                                    
                        
                     EPIQ 7 Ultrasound Machine Repair
                                                                                        
                                                        
                        
                        
                        
                                                            EPIQ 7 Ultrasound Machine Repair
                                                    
                        
                     IE33 Ultrasonic Diagnostic Instrument Common Fault
                                                                                        
                                                        
                        
                        
                        
                                                            IE33 Ultrasonic Diagnostic Instrument Common Fault
                                                    
                        
                     GE Vivid7 Ultrasound Machine Maintenance Run Failure
                                                                                        
                                                        
                        
                        
                        
                                                            GE Vivid7 Ultrasound Machine Maintenance Run Failure
                                                    
                        
                     SSA 580A Toshiba System Repair , clinic RX board maintenance
                                                                                        
                                                        
                        
                        
                        
                                                            SSA 580A Toshiba System Repair , clinic RX board maintenance
                                                    
                        
                     Clinic Acuson Ultrasound Machine Repair For Display Problem
                                                                                        
                                                        
                        
                        
                        
                                                            Clinic Acuson Ultrasound Machine Repair For Display Problem
                                                    
                        
                     IU22 Ultrasonic Machine Repair No Display Failure
                                                                                        
                                                        
                        
                        
                        
                                                            IU22 Ultrasonic Machine Repair No Display Failure
                                                    
                        
                     KTI301394-2 Ultrasound Machine Repair GE Voluson E6 Voluson E8 RSR
                                                                                        
                                                        
                        
                        
                        
                                                            KTI301394-2 Ultrasound Machine Repair GE Voluson E6 Voluson E8 RSR